Estimate upgrade time

Review the following considerations to ensure that you provide adequate scheduled maintenance windows to complete the upgrade.

Use the following table to calculate the time to upgrade the software and firmware on each component. If the Converged System that you are upgrading does not have a specific component in the table, skip that component.

  • For cluster configurations, include both the primary and the subordinate components in the calculated time for the component.
  • Plan your upgrade maintenance windows according to your environment. Do not upgrade all hosts at the same time. Retain an adequate number of hosts in a connected state to reduce impact to production traffic.
  • For each upgrade task, record the total estimated upgrade time in the Your Calculated Time column of the following table.
NOTE: The estimates do not include the time for preparation, configuration, backup, and download. Estimated times are may differ depending on applications running on your Converged System.
Order Component Minimum upgrade time (minutes) Restart Required Your Calculated Time
1

VMware vCenter Server Appliance with external PSC

60 Yes
2 VMware vCenter for Windows Migrate or vCSA upgrade 60 Yes
3 VMware ESXi hosts 35 per host Yes
4 Virtual Machines hardware version and VMware Tools 10 Yes

The following table provides an estimated time based on the size of the database and the migration:

Database size 40 GB 75 GB 150 GB 250 GB
Migrating inventory and configuration data only (7 GB database) 30 minutes 30 minutes 30 minutes 30 minutes
Migrating inventory, configuration, event, and task data 1 hour, 4 minutes 1 hour, 49 minutes 3 hours, 19 minutes 5 hours, 48 minutes
Migrating all data (including performance and other historical data) 1 hour, 40 minutes 3 hours, 8 minutes 6 hours, 22 minutes 10 hours, 45 minutes